Current Sensor Offset Calibration Method using Dual Sensor for trans-less PV Inverter
듀얼 센서를 이용한 무변압기형 태양광 인버터 전류 센서의 오프셋 보정 방법
- Hong, Ki-Nam (Dept. of Embedded Software Eng. Kangwoon Univ.) ;
- Choy, Ick (Dept. of Information and Control Eng. Kangwoon Univ.) ;
- Choi, Ju-Yeop (Dept. of Electrical Eng. Kangwoon Univ.) ;
- Lee, Young-Kwon (Keumbee Electronics Co.)
- Published : 2012.03.29
Abstract
Since PV PCS uses output current sensor for ac output current control, the sensor's sensing value includes unnecessary offset inevitably. If PV inverter is controlled by the included offset value, it's output current will generate DC offset. The DC offset of output current for trans-less PV inverter is fatal to grid, which results in saturating grid side transformer. Usually DSP controller of PV inverter reads several times sensing value during initial operation and, finally, it's average value is used for offset calibration. However, if temperature changes, the offset changes, too. Therefore, output current sensor measures sensing value that includes offset again. In this paper we propose new algorithm where two identical forward and reverse sensors are used to calculate the offset in real time. As a result the offset is not correlated with temperature change. The proposed algorithm is verified through PSIM simulation for validity.
Keywords