Multi-frequency bands receiver system and its test observation results
초록
Over the past several years the millimeter wave VLBI(Veryl Long Baseline Interferometry) observations have been intensively carried out. However In millimeter and sub-millimeter waves observations for VLBI, it is crucial to calibrate correctly the phase variations of the electromagnetic waves propagation through the troposphere. To do this, KVN(Korean VLBI Network) has a unique multi-frequency bands receiver system which is able to perform the simultaneous observations in up to four bands such as 22, 43, 86, and 129GHz. The phase of a source at 22GHz can be used to calibrate the phase of the same source at higher frequency bands. The phase calibration using multi-frequency bands receiver system is possible because the phase fluctuations from a given amount of waver vapor increase linearly with frequency. That is to say that troposphere is non-dispersive property in terms of tropospheric delay fluctuations. In this talk, We present results of test observation for multi-frequency bands receiver system.
키워드