지반침하 기인 저압 증기터빈 케이스 진동 저감

Vibration Reduction of a LP Turbine Casing due to Subsidence

  • 발행 : 2011.10.27

초록

The vibration of a LP turbine casing may cause the problems of power generation and the life of its facility. In this study, we carried out on-site measurements of a LP Turbine in order to find the cause of the vibration and conducted experimental and numerical modal analysis of the turbine with its support frame. The measurement and the modal analysis show that the natural frequency of the turbine becomes close to 60 Hz due to the subsidence of the support. The elimination of the subsidence by shimming between the turbine and the support frame gave rise to the reduction of the vibration of the LP turbine case.

키워드