A Study on Vibration Reduction of Local Structure of Medium-speed Diesel Engine

중속 디젤엔진 국부 구조물의 진동저감 연구

  • 정건화 (현대중공업(주) 엔진연구실) ;
  • 이준호 (현대중공업(주) 제품개발연구소 엔진연구실) ;
  • 손정호 (현대중공업(주) 제품개발연구소 엔진연구실) ;
  • 류영석 (현대중공업(주) 엔진기계사업본부 엔진기술개발부)
  • Published : 2011.10.27

Abstract

The failures of local structure of marine medium-speed diesel engine occurred in durability test. The vibration response of the whole engine was in an acceptance level, but the local structures were broken. ODS test and vibration measurement were carried out in order to investigate the root cause of durability problem. These tests revealed that the root cause of failures was excessive vibration by $4.5^{th}$ resonance between engine body and local structure. The best solution to reduce the vibration response is to change the type of mount. After a rigid mount was replaced by a flexible mount, maximum vibration level dropped to 72%.