연료전지 블로워의 유로 크기에 따른 소비전력과 소음저감 방법

Reduction of Noise and Input Power in Fuel Cell Blower by Controlling Flow Path

  • 발행 : 2011.11.16

초록

This paper describes performance enhancement of a fuel cell's blower by controlling flow path. Different duct diameter at the inlet and outlet of the blower is selected for reducing blower noise level and input power. Hole diameter and the number of hole at the check valve are tested to reduce the input power of the blower. Two types of blower, fuel pressurized blower and cathode blower, are considered in the present study. Throughout experimental measurements of the test blowers, it is found that duct diameter is effective to reduce noise level and input power in the fuel cell blower. Noise reduction due to the optimal duct diameter at the outlet is more effective when flow rate is relatively large. That is, cathode blower has larger noise reduction compared to fuel pressurized blower because of larger flower rate. Input power of the blower can be reduced by controlling the hole diameter and the number of hole at the check valve.

키워드