Research about VVVF direct subways Secondary source unit(SIV)180KVA for using Filter Capacitor(FC) maintenance & limit of use

VVVF 직류전동차의 보조전원장치(SIV)180KVA용에 사용되는 필터콘덴서(FC) 유지보수 및 사용한도에 관한 연구

  • 신혜진 (서울산업대학교, 철도차량공학과) ;
  • 우석태 (서울산업대학교, 철도차량공학과) ;
  • 신민호 (서울산업대학교, 철도차량공학과) ;
  • 손영진 (서울산업대학교, 철도차량공학과)
  • Published : 2010.06.10

Abstract

First, In this essay we research about secondary source unit(SIV)180KVA is install on VVVF direct subways for using Filter Capacitor(FC) maintenance & limit of use. Vehicle's extendly use and congestly at load for Catenary voltage and load change about output change and in SIV unit there are important device named GTO Thyristor, Power Transistor Module device become short and it often happen. We analysis the fault cause and there are effects and we know the secondary source unit in filter capacitor FC1~4 input harmonic distortion component's filtering don't do correctly so we study the capacitor extend use for the component change and the outside condition by slow property changed happen and we check before and when its fault, its difficult to measure. Finally, In this research we care for this reason and we study about capacitor maintenance through control and measure ways improvement and capacitor's life spans limit of use.

본 논문에서는 현재 VVVF 직류전동차에 장착되어 있는 보조전원장치(SIV)180KVA용에 사용되는 필터콘덴서(FC) 유지보수 및 사용한도에 관한 연구를 수행하였다. 차량의 장기사용에 따른 내구연한과 혼잡도 부하에 따른 가선전압 변동 및 부하변동에 대해 출력 전압값의 변화와 SIV장치내 중요소자인 GTO Thyristor, Power Transistor Module 소자가 단락되는 현상이 자주 발생되는 등 고장원인을 분석해 본 결과 보조전원 장치내 필터 FC1~4 캐패시터의 입력측 고조파 성분의 필터링이 제대로 되지 못하는 것을 알게 되었으며, 캐패시터의 장기 사용에 따른 성분변화와 외부조건에 의해 천천히 특성변화를 일으킴으로써 사전 점검방법 및 불량 시 측정하기 어렵다는 점을 착안하여 본 연구를 검토하였다. 이를 위하여 본 연구에서는 캐패시터의 유지보수를 통한 관리와 측정방법의 개선점, 캐패시터의 수명 사용한도에 대해 검토하였다.