Damage Detection of Decrepit Tunnel Structures using the NDT
비파괴 검사법에 의한 노후터널의 건전도 평가
- Kim, Dong-Gyou (Department of Geotechnical Engineering and Tunnelling research division, KICT) ;
- Jung, Ho-Seop (Department of Geotechnical Engineering and Tunnelling research division, KICT)
- Published : 2010.03.25
Abstract
Recently, the construction of road, subway, railroad, and microtunnel for electricity supplement have been increased because of increasement of traffic in urban area, increasement of industrial transportation, and the network between cities in Korea. The deterioration of tunnel structure may occur by various internal and external factors and particularly, tunnel structures tend to contact with either underground water or harmful ions. Therefore, leakage sometimes occurred through the cracks and joints of concrete lining. The leakage in tunnel may affect the durability of concrete lining. In this study, to evaluate the durability and deterioration of concrete lining in tunnel structures, we were performed the various experiments for compressive strength. Compressive strength obtained from nondestructive inspection and compressive strength test varies according to the concrete lining conditions.