Estimation of Cadmium Removal Capacity on Furnace Slag in the Change of Initial Concentration and pH

초기농도와 pH 조건의 변화에 따른 제강슬래그의 카드뮴 제거능 평가

  • Lee, Gwang-Hun (Dept. of Civil and Environmental Engineering, Seoul National University) ;
  • Kim, Eun-Hyup (Dept. of Civil and Environmental Engineering, Seoul National University) ;
  • Park, Jun-Boum (Dept. of Civil and Environmental Engineering, Seoul National University) ;
  • Oh, Myoung-Hak (Korea Ocean Research and Development Institute)
  • 이광헌 (서울대학교 공과대학 건설환경공학부) ;
  • 김은협 (서울대학교 공과대학 건설환경공학부) ;
  • 박준범 (서울대학교 공과대학 건설환경공학부) ;
  • 오명학 (한국해양연구원)
  • Published : 2010.03.25

Abstract

This study was focused on the reactivity of furnace slag against cadmium to design the vertical drain method with reactive column for improving contaminated sea shore sediment. The removal capacity of furnace slag was analyzed using pseudo-second-order model. And the effective parameters of removal test were initial concentration and initial pH. According to equilibrium removal amount and reactive constant calculated by pseudo-second-order model, the removal capacity was analyzed. Equilibrium removal amount of furnace slag was linearly increased as increasing intial cadmium concentration. Because the pH was around 11, the removal mechanism of furnace slag could be both sorption and precipitation. Therefore the removal amount was increased due to initial concentration. pH was increased to around 11 in the case of "No treat", but the pH were 3.8 in the case of "HAc added" and 0.7 in the case of "HCl added". The removal amount was different 4.8, 1.19 and 0.27 mg/g. This results show the pH was major factor to remove cadmium using furnace slag.

Keywords