Characteristic of Facing Discharge Front plate Address Electrode Structure in AC PDP

  • Cho, Hyun-Min (Dept. of Electrical Engineering, Pusan National University) ;
  • Kim, Dong-Hwan (Dept. of Electrical Engineering, Pusan National University) ;
  • Song, In-Cheol (Dept. of Electrical Engineering, Pusan National University) ;
  • Kim, Yun-Gi (Dept. of Electrical Engineering, Pusan National University) ;
  • Ok, Jung-Woo (Dept. of Electrical Engineering, Pusan National University) ;
  • Kim, Dong-Hyun (Dept. of Electrical Engineering, Pusan National University) ;
  • Lee, Hae-June (Dept. of Electrical Engineering, Pusan National University) ;
  • Lee, Ho-Jun (Dept. of Electrical Engineering, Pusan National University) ;
  • Park, Chung-Hoo (Dept. of Electrical Engineering, Pusan National University)
  • Published : 2009.10.12

Abstract

In order to improve discharge characteristics in AC PDP, we suggest FDFA (Facing Discharge Front plate Address Electrode) structure. By adopting both long facing discharge electrodes and address electrodes in front plate, the FDFA structure make it possible to gain a high luminance, low power consumption, and a high luminous efficiency.

Keywords