Rheological Characteristics of Fiber-Reinforced High-Strength AFR Concrete

섬유보강 고강도 내화콘크리트의 레올로지 특성 분석

  • 최선미 (대한주택공사 주택도시연구원 건설기술연구실) ;
  • 이범식 (대한주택공사 주택도시연구원 건설기술연구실) ;
  • 배기선 (대한주택공사 주택도시연구원 건설기술연구실) ;
  • 김상연 (대한주택공사 주택도시연구원 건설기술연구실) ;
  • 박수희 (대한주택공사 주택도시연구원 건설기술연구실)
  • Published : 2009.05.07

Abstract

The fiber(NY, PP) known to the effective material on improvement of the fire-resistance of HSC(high strength concrete) has a difference for fluidity according to the variation of a length and contents of fiber. In this study, to analyze the effect of a length and contents of the fiber on the fluidity of HSC and fheological characteristics, we calculated a viscosity of mortar by mini slump-flow, simple V-lot and viscometer. With the test results, the fluidity characteristic showed a moderate difference by a length and contents of the fiber, but showed a significant difference by increase of the fiber contents. ${\ast}$ AFR Concrete (Advenced Fire Resistant Concrete)

고강도콘크리트의 내화성능 증진에 효과적인 것으로 알려진 섬유(NY, PP)는 섬유의 길이조합과 혼입율에 따라 유동성에 차이가 있다. 본 논문에서는 섬유의 길이조합과 혼입율이 고강도콘크리트의 유동성과 레올로지 특성에 미치는 영향을 분석하기 위하여 몰탈시험체를 대상으로 미니 슬럼프 플로우(Mini slump-flow), 간이 V-lot 및 회전점도계에 의한 점도측정을 수행하였다. 실험결과, 섬유의 길이 조합에 따른 유동특성은 큰 차이가 없으나 섬유혼입률이 증가할수록 점도는 큰 것으로 나타났다.

Keywords