컴퓨터용 라디에이터의 열전달 및 유동특성 평가

Heat Transfer and Fluid Flow Evaluation of Radiator for Computer Cooling

  • 차동안 (서울시립대학교 기계정보공학과) ;
  • 권오경 (한국생산기술연구원 에너지설비기술지원센터) ;
  • 윤재호 (한국생산기술연구원 에너지설비기술지원센터) ;
  • 오명도 (서울시립대학교 기계정보공학과)
  • 발행 : 2009.06.25

초록

The performance of louver-finned flat-tube and fin & tube radiators for computer CPU liquid cooling were experimentally investigated. In this study, 7 samples of radiators with different shape and pass number (1, 2, 10) were tested in a wind tunnel. The experiments were conducted under the different air velocity range from 1 to 4 m/s. The water flow rate through a pass was 1.2 LPM. Inlet temperatures of air and water were $20^{\circ}C$ and $30^{\circ}C$ respectively. It was found that the best performance was observed in the louver-finned flat-tube sample considering pressure drop and heat transfer coefficient.