Combustion Characteristics of a Staged Burner for a Boiler

다단 연소 버너의 보일러 연소실에서의 연소 특성

  • 안준 (한국에너지기술연구원) ;
  • 김종진 (한국에너지기술연구원) ;
  • 강새별 (한국에너지기술연구원)
  • Published : 2008.03.26

Abstract

The demand for a boiler with low NOx burner is increasing with the recent strict NOx regulation. Staged burner is a common low NOx burner to suppress the formation of thermal NOx by yielding local fuel rich and fuel lean condition. The staged burner gives fire with bigger frontal area and length compared with a conventional burner, which changes heat transfer characteristics in the combustion chamber. The heat transfer and exhaust gas characteristics has been studied in the present study for a 0.5 t/h class furnace type boiler adopting the staged burner. A numerical simulation has been conducted to clarify the detailed physics inside the combustion chamber.

Keywords