Experimental Study on the Inelastic Behavior of Single-layer Latticed Dome

단층 래티스 돔의 비탄성 거동에 대한 실험연구

  • 김종수 ((주)CS구조엔지니어링) ;
  • 김상대 (고려대학교 건축사회환경공학과) ;
  • 김명한 (대진대학교 건축공학과) ;
  • 오명호 (목포대학교 건축공학과) ;
  • 신창훈 ((주)CS구조엔지니어링)
  • Published : 2008.05.02

Abstract

This study discusses the inelastic behavior of single-layer latticed dome, composed of tubular truss member and newly proposed joint sections, through loading test on the scale-down structure. The loading test was performed under displacement control conditions, using loading transfer system for the same value of point loads on all joints. Maximum applied load was nearly 1.6 times of the design load, and inelastic buckling occured beyond compressive yeilding in some members. The displacement of structure was maimtained upto the limit of oil jack. The behavior of latticed dome from the loading test was analyzed on the view of structural design practice.

본 논문에서는 새로이 제안된 접합부를 가진 단층 래티스 돔의 비탄성 거동을 실험적으로 분석하였다. 구조적인 성능과 시공성을 모두 만족시키기 위해서 제안된 새로운 접합부를 적용하여 강관으로 구성된 스팬 7m의 축소 실험모델을 제작하였으며, 하중 전이장치를 이용하여 각 절점에 균일한 하중이 가력되는 정적 재하실험을 수행하였다. 최대 가력하중은 설계하중의 약 1.6배였으며, 일부 부재에서 압축 항복점을 넘어 비탄성 좌굴이 발생하였다. 좌굴 발생 이후에는 가력장치가 허용할 수 있는 변위까지 실험을 수행하였으며, 실험을 통해서 구해진 래티스 돔의 거동을 구조설계의 관점에서 분석하였다.

Keywords