불평형전류 측정에 의한 회전기 열화감시장치
Deterioration Monitoring Device by Unbalance Current Measurement of Rotating Machines
초록
This paper described an on-line condition monitoring device for rotating machines by measurement of unbalance current due to insulation deterioration. The device consists of a zero-phase current transformer (ZCT), a low-noise amplifying circuit, and a microprocessor unit. The prototype device measures current of
키워드