발코니 확장에 따른 수직화염 확대 위험성에 관한 실험적 연구

An Experimental Study on the Risk of Vertical Flame for a Extended-Balcony

  • 신이철 (호서대학교 소방방재학과) ;
  • 윤유혁 (호서대학교 소방방재학과) ;
  • 이주희 (호서대학교 혁신기술.경영융합대학원 메카트로닉스공학과) ;
  • 권영진 (호서대학교 소방방재학과)
  • Shin, Yi-Chul (Fire & Disaster Protection Engineering of Hoseo Univ.) ;
  • Youn, Yoo-Hyuk (Fire & Disaster Protection Engineering of Hoseo Univ.) ;
  • Lee, Ju-Hee (Department of Mechatronics Eng. Hoseo Univ.) ;
  • Kwon, Young-Jin (Fire & Disaster Protection Engineering of Hoseo Univ.)
  • 발행 : 2008.11.13

초록

Since installing a balcony can significantly reduce the spread of fire, fire spread to the upper levels was confirmed, comparing the cases with and without balcony extension. It was confirmed that the fire can spread not only to the next higher level but also to two levels higher due to the outburst of flame which reached a significant temperature in the case without balcony, while the possibility of fire spread to the upper level reduced considerably with the balcony. this study is compared and analyzed to vertical diffusion appearance of an externally venting flame. An installed balcony is also applied to fire test 6.54kW to analyze about effect of a balcony.