Reduction of Power Ripples in a Doubly Fed Induction Generator Under Current Measurement Errors

DFIG의 전류 측정오차로 인한 발전전력의 리플 저감에 관한 연구

  • Published : 2007.11.30

Abstract

In doubly fed induction generators (DFIGs), control of rotor currents allows for adjustable speed operation, active, and reactive power control. This paper presents a DFIG control strategy that enhances the active and reactive power control with controllers that can compensate for the errors caused by current measurement path in the DFIG system. The errors can be divided into two categories: offset and scaling errors. These can induce the speed, active, and reactive power pulsations, which are one and two times the fundamental slip frequency in the DFIG. And these undesirable ripples can do the DFIG harm. In this paper, a new compensation algorithm is proposed. Therefore, the proposed algorithm has several advantages: to implement is easy; it require less computation time; it is robust with regard to the variation of the induction generator parameters. In this paper, a new algorithm is introduced by using the integral of phase currents to measure the current ripples of rotor-side converterin the DFIG system. The experiment results are shown the effectiveness of the proposed method.

Keywords