Experimental Study on the Flame Stable Region of Natural Gases from Various Producing Districts
산지별 천연가스의 화염 안정영역에 관한 실험적 연구
- Lee, Chang-Eon ;
- Hong, Sung-Chang ;
- Jeong, Young-Sik ;
- You, Hyun-Seok ;
- Lee, Seung-Jun ;
- Her, Jae-Young ;
- Hwang, Cheol-Hong
- 이창언 (인하대학교 기계공학과) ;
- 홍성창 (인하대학교 대학원 기계공학과) ;
- 정영식 (어코드(주)) ;
- 유현석 (한국가스공사 연구개발원) ;
- 이승준 (한국가스공사 연구개발원) ;
- 허재영 (한국가스공사 연구개발원) ;
- 황철홍 (인하대학교 기계공학과)
- Published : 2007.05.04
Abstract
In this study, the difference of flame stability zone for natural gases from producing districts was studied experimentally using a new type of flame stability diagram. The similarity of stable flame zone between a domestic appliance and an interchangeability test(IT) burner is also examined. As a result, the stable flame zones expressed by limits curves of flame lifting and yellow tipping show the similar results in a domestic gas range and IT burner. Furthermore, IT burner can reproduce the flash back phenomena and show the distinct difference of fuel type as the burner diameter is increased. To suggest the new type of flame stability diagram in the respect of fuel interchangeability, the air flowrate and Wobbe fuel flowrate were adopted as axis coordinates. It can be identified that the new diagram can provide the useful information on the difference of flame stability zone, heat input rate and air-fuel ratio when a fuel is altered to other fuels under the identical operating conditions. Finally, the stable flame zones for natural gas of 6 type are compared, and the detailed information to use as the interchangeability fuels of standard natural gas is provided using the new type of flame stability diagram.