한국철도학회:학술대회논문집 (Proceedings of the KSR Conference)
- 한국철도학회 2007년도 춘계학술대회 논문집
- /
- Pages.816-823
- /
- 2007
전차선로 순환전류 발생원인과 대책에 관한 연구
A Study on Causes and Measures Against Occurrence of Circulating Current in catenary
초록
Electric car tract plays the role of supply high electric power to the electric car from the substation by using Pantograph of the electric car. It is always exposed to the external atmosphere, which results in quite substantial fluctuations in current and voltage during operation of electric car. This generates possibility of occurrence of accident at all times. Since range of wiring metallic globe installed on the catenary cannot achieve complete electrical contact, accidents are occurring due to circulating current caused by arc caused by incomplete contact due to occurrence of hairline fracture of Pantograph due to pressure or vibration of wiring. Furthermore, rapid increase in the operational current due to increase in the operational frequency of the electric car is causing erosion and short circuit of the metallic globe at the contact points. This study on arc is generated as current transmitted out of the substation courses through power line or wiring metallic globe other than the main circuit as the current is being collected at the electric car through feeder and feeder divergence device. Accordingly, since heat generated by the arc becomes the cause for generation of circulating current due to melting of metal or softening of metal due to increase in temperature accompanying increase in contact resistance, this research shall describe causes and measures against occurrence of circulation current.
키워드