In-situ optical thickness & easy packing density measurements as novel approach to development of OLED

  • Published : 2007.08.27

Abstract

Optical thickness method using double interferometer showed dynamic variations of both mechanical and optical thicknesses. Packing density measured a thickness ratio of before and after pressed single film. Lower swelled thickness of emitting layer in a device and densely packed film had shown better lifetime.