Grading of Architectural Plumbing Noise using Psycho-Acoustic Experiment

청감실험을 이용한 건축설비소음의 등급화

  • 유희종 (원광대학교 건축음향연구실) ;
  • 정철운 (원광대학교 건축음향연구실) ;
  • 김재수 (원광대학교 공과대학 건축학부)
  • Published : 2007.11.15

Abstract

Since Equipment-Noises occurring in machine room penetrate wall-body and travel to the adjacent room in the form of air-borne sound and structure-borne sound, it is appearing as the main factor that injures a peaceful residential environment, and due to this, such noise-damage is currently increasing rapidly. Consequently, despite the measures for sound-insulation and soundproof against the equipment-noise penetrated wall-body is urgently required, but as the subjective evaluation considered for psychological response about the equipment-noise was not practiced, many dissatisfactions are still raising even after some measure was taken. On such point of view, this Research, at the spot, has actually measured the equipment-noise that had permeated various wall-bodies, and examined its physical characteristics, thence based upon this, has conducted Psycho-Acoustics Experiment and investigated the interrelation between the physical evaluation value and psychological reaction value. It is considered that such study result could be utilized as the useful material at the time of establishment of the Grading Standard for the insulation performance against the Architectural Plumbing Noise, in the future.

Keywords