Study of fire protection performance of newly developed cementitious fire protection material for application to architectural building

건축구조물에 적용하기위한 신개발 시멘트계 내화재료의 내화성능에 관한 연구

  • 김장호 (세종대학교 토목환경공학과) ;
  • 박해균 (세종대학교 토목환경공학과) ;
  • 이명섭 (삼성물산(주) 토목사업본부) ;
  • 원종필 (건국대학교 사회환경시스템공학과) ;
  • 임윤묵 (연세대학교 토목환경공학과) ;
  • 이경민 (세종대학교 토목환경공학과)
  • Published : 2006.11.04

Abstract

High-rise and large size buildings require high strength concrete and steel structure as a necessity. However, high strength concrete and steel structure are strong material but have a weakness to high temperature. Therefore, fire protection is a matter that must be considered very importantly in design for structure of high strength concrete and steel. Fire proof board that is existing method for fire proof has relatively low performance in fire protection emphasizes the need of new fire protection material due to the using of in numerable inflammables like plastics. The objective of this study is to understand the fire-resisting performance of newly developed fire protection material for building. This paper describes the results of fire tests using ISO curve that is fire protection regulation for buildings of the newly developed cementitious fire protection coating material applied concrete tunnel lining specimens.

Keywords