Strengthening of Concrete Structures with External Post-Tensioning and CFRP Strips

외부 프리스트레싱과 탄소섬유판을 결합한 콘크리트 구조물 보강

  • 임동환 (동서대학교 건설공학부 토목공학과) ;
  • 박성환 (동서대학교 대학원 토목공학과) ;
  • 김용일 (동서대학교 대학원 토목공학과)
  • Published : 2006.11.04

Abstract

Carbon fiber reinforced polymer(CFRP) have superior mechanical and chemical properties in comparison with conventional materials. And post-tensioning method has been used for structural reinforcement of RC structures due to easy installation and good effect of resisting capacity of structures. But the higher cost of CFRP and the loss of prestressing force with time are considered the major problems to use it. In this study, CFRP Strips and external post tensioning for rehabilitation of old concrete structures were adapted and optimal combination of these methods is considered. A total of 17 concrete members were made and tested. The types and numbers of CFRP strips and post-tensioning types were selected as major test variables. From test results, it is shown that the concrete members that post tensioned and bonded CFRP strips has a pronounced effect on the strength and deformational behavior. This present study indicates that external temporally post tensioning can reduce the amount of CFRP strips required and the combination of temporally post tensioning and CFRP strips may meet the strength and ductility requirements of old structures.

Keywords