한국전산구조공학회:학술대회논문집 (Proceedings of the Computational Structural Engineering Institute Conference)
- 한국전산구조공학회 2006년도 정기 학술대회 논문집
- /
- Pages.256-263
- /
- 2006
실시간 하이브리드 실험법을 이용한 동조액체댐퍼가 설치된 건물의 진동제어
Vibration Control of a Building Structure with a Tuned Liquid Damper Using Real-Time Hybrid Experimental Method
초록
In this paper, an experimental hybrid method, which implements the earthquake response control of a building structure with a TLD(Tuned Liquid Damper) by using only a TLD as an experimental part, is proposed and is experimentally verified through a shaking table test. In the proposed methodology, the whole building structure with a TLD is divided into the upper TLD and the lower structural parts as experimental and numerical substructures, respectively. At the moment, the control force acting between their interface is measured from the experimental TLD with shear-type load-cell which is mounted on shaking table. Shaking table vibrates the upper experimental TLD with the response calculated from the numerical substructure, which is subjected to the excitations of the measured interface control force at its top story and an earthquake input at its base. The experimental results show that the conventional method, in which both a TLD and a building structure model are physically manufactured and are tested, can be replaced by the proposed methodology with a simple experimental installation and a good accuracy for evaluating the control performance of a TLD.