Operating condition and air pollutant emission when do RPF co-combustion in coal fluid bed boiler

석탄유동층 보일러에 RPF 혼소시 운전조건 및 대기오염물질 배출 특성 변화

  • 윤균덕 (산업기술시험원 환경기술본부 환경설비팀) ;
  • 박인출 (산업기술시험원 환경기술본부 환경설비팀) ;
  • 박종경 (산업기술시험원 환경기술본부 환경설비팀) ;
  • 조연행 (산업기술시험원 환경기술본부 환경설비팀) ;
  • 최연석 (한국기계연구원) ;
  • 선도원 (한국에너지기술연구원) ;
  • 박도현 (부산염색공단)
  • Published : 2006.06.22

Abstract

Because price of fossil fuel rises, necessity about alternative energy was risen. Studied co-combustion of RPF to coal fluid bed boiler by necessity of these althernative energy. Purpose of this study to coal fluid bed bioler RPF when did co-combustion, change operating condition and characteristic of air pollutant examine according to change of fuel characteristic, operating condition examined about combustion chamber temperature, oxygen content etc. and air pollutant examined about material that is included to allowable exhaust standard and dioxin. Co-combustion condition was 5%. It was no peculiar under test result operating condition. Concentration of Co and HCl rose according as do RPF co-combustion and the other pollutants had hardly changed. Dioxin is low concentration level more than $0.1ng-TEQ/Sm^3$. There was no pollutant that exceed akllowable exhaust standard for boiler but $SO_x,\;NO_x$ were exceeded about allowable exhaust standard for incinerating facility.

Keywords