A study on the safety about Contact wire uplift of a metro-railroad bridge section

도시철도 교량구간의 전차선 압상량에 대한 안전성 연구

  • 장우진 (서울산업대학교 전기공학과) ;
  • 조용현 (한국철도기술연구원) ;
  • 이기원 (한국철도기술연구원) ;
  • 소선영 (서울메트로 기술본부) ;
  • 박종학 (서울메트로 기술본부) ;
  • 이재봉 (서울산업대학교 철도전문대학원, 서울메트로 기술본부)
  • Published : 2006.11.09

Abstract

There are 5 railway bridges in a Seoul metro network; Jamsil, Dangsan(line 2), Dongho(line 3), Dongjak(line 4) and Chungdam(line 7). Because there are strong wind and vibration in the bridges, uplift of a contact wire caused by pantographs in the bridge section is higher than in a normal section. If the uplift at the support point exceed 10 cm, an interference between pantographs and catenary system happens. Estimated maximum uplift is obtained by applying safety factor 2 to the simulation results. The application of the safety factor is needed for taking into account of the effect of the wind, etc. Previously, we can not check whether or not the safety factor is proper. Recently, we can measure the uplift during the train operation, as a telemetry system which can measure dynamic behavior of the contact wire has been developed. The aim of this research is to review how proper the safety factor related to the uplift is, based on the measurement. We performed simulations and experiments for the uplift at the Jamsil railway bridge. The simulations were performed for the every kind of the train passing the Jamsil bridge. In order to compare the analysis results with the measurement results, we measured the uplifts at the support when the trains passed the measuring point. Finally, we proposed adequate safety factor with the uplift for the bridge section.

Keywords