Measurement of sound Insulation of small-size windows

소형 창문의 차음성능 측정에 관한 고찰

  • 김상렬 (한국기계연구원 음향소음팀) ;
  • 강현주 (한국기계연구원 음향소음팀) ;
  • 김재승 (한국기계연구원 음향소음팀) ;
  • 김현실 (한국기계연구원 음향소음팀) ;
  • 김봉기 (한국기계연구원 음향소음팀)
  • Published : 2006.11.16

Abstract

In order to measure the sound transmission loss(STL) of a test specimen such as windows, which is smaller than the test opening, a special partition is built into the test opening and the specimen is placed in that partition. This paper discusses how the measured STL is changed by the partition when a small-size window of high sound insulation is mounted. Theoretical and experimental investigations are carried out to quantify the effect of the filler wall. The results reveal that the smaller the window size is, the higher sound insulation performance of the filler wall is required in order to measure the accurate STL of the specimen. It is found that the insufficient sound insulation of the filler wall leads to the lower measured value of the window's STL.

Keywords