공압능동제어를 이용한 저주파 영역에서의 공압제진대 제진성능 개선에 대한 연구

Performance Enhancement of Pneumatic Vibration Isolation Tables in Low Frequency by Active Control

  • 오기용 (한국과학기술원 기계공학과) ;
  • 이정훈 (한국과학기술원 기계공학과) ;
  • 김광준 (한국과학기술원 기계공학과) ;
  • 신윤호 (한국과학기술원 기계공학과)
  • 발행 : 2006.11.16

초록

As environmental vibration requirements on precision equipment become more stringent. use of pneumatic isolators has become more popular and their performance is subsequently required to be further improved. Dynamic performance of passive pneumatic isolators is related to various design parameters in a complicated manner and, hence, is very limited especially in low frequency range by volume of chambers. In this study, an active control technique, so called time delay control which is considered to be adequate for a low frequency or nonlinear system, is applied to a single chamber pneumatic isolator. The procedure of applying the time delay control law to the pneumatic isolator is presented and its effectiveness in enhancement of transmissibility performance is shown based on simulation and experiment. Comparison between passive and active pneumatic isolators is also presented.

키워드