Proceedings of the Korean Geotechical Society Conference (한국지반공학회:학술대회논문집)
- 2006.03a
- /
- Pages.970-979
- /
- 2006
An experimental study on the effect of deterioration of drainage system on tunnel structures
배수시스템 수리기능저하가 터널구조물에 미치는 영향에 대한 실험적 연구
- Kwon, Oh-Yeob (Dept. of Civil Engineering, Konkuk Univ.) ;
- Shin, Jong-Ho (Dept. of Civil Engineering, Konkuk Univ.) ;
- Yang, Yu-Hong (Saman Engineering Co. Geotechnical Dept.) ;
- Joo, Eun-Jung (Dept. of Civil Engineering, Konkuk Univ.)
- Published : 2006.03.24
Abstract
Construction of underground structure requires higher standard of planning and design specifications than in surface construction. However, high construction cost and difficult working environment limit design level and construction quality. One of the most sensitive factors to be considered are infiltration and external pore-water pressures. Development of pore-water pressure may accelerate leakage and cause deterioration of the lining. In this paper, the development of pore-water pressure and its potential effect on the linings are investigated using physical model tests. A simple physical equipment model with well-defined hydraulic boundary conditions was devised. The deterioration procedure was simulated by controlling both the permeability of filters and flowrate. Development of pore-water pressure was monitored on the lining using pore pressure measurement cells. Test results identified the mechanim of pore-water pressure development on the tunnel lining which is the effect of deterioration of drainage system. The laboratory tests were simulated using coupled numerical method, and shown that the deterioration mechanism can be reproduced using coupled numerical modelling method.