에탈론 필터를 이용한 광섬유격자 센서의 선형 복조
Linear interrogation of fiber Bragg grating sensor array using a Etalon filter
초록
A scanned Fabry-Perot(F-P) filter and a Multi-Channel Wavelength Locker(MCWL) were used to interrogate fiber Bragg grating sensor array. When the F-P filter scans over the MCWL which works as a multi-reference the temporal peaks profiles correspond to the locking wavelengths. To solve the linearity, stability, and accuracy problems caused by the nonlinear response of F-P filter, a polynomial fitting algerian was used to calculate the relationship between the peak locations and the wavelengths in all the scanning range. Then from the reflected peaks locations and the best fitting line, the Bragg wavelengths can be obtained. The measurement linearity was greatly enhanced with wavelength resolution of about 4 pm in 10Hz scanning frequency.