동조액체감쇠기의 진동제어 성능연구

A Study on Control Performance of Tuned Liquid Damper

  • 우성식 (단국대학교 건축공학과) ;
  • 우운택 (단국대학교 건축대학 건축공학과) ;
  • 정란 (단국대학교 건축대학 건축공학과)
  • 발행 : 2005.03.18

초록

This paper presents the results of experimental investigations on the response control performance of tuned liquid damper(TLD). Steel frame building model is used for the experiments. Shaking table is controled by velocity consol. Experimental variables are mass ratios(${\mu}=mass$ of TLD/mass of structure), shape ratio(depth of water/ length of TLD), number of nets(N) and tuned frequency ratio($f_l/f_s$). Results show that the greater the mass ratio is, the better the control performance is. So, it can be concluded that TLD is able to be used as a device of vibration control in the remodeling of existing buildings that are not designed to resist earthquake

키워드