Improved IPMCs and It's Application for Flapping Actuator

IPMCs(Ionic Polymer Metal Composites) 성능 개선 및 날갯짓 작동기로의 응용

  • 이순기 (건국대학교 신기술융합학과) ;
  • 유영태 (건국대학교 신소재공학과) ;
  • 허석 (건국대학교 인공근육센터) ;
  • 박훈철 (건국대학교 항공우주공학과)
  • Published : 2005.11.01

Abstract

The two major obstacles in the application of IPMC to flapping actuators operated in the air are solvent loss and actuation force. In this paper, solvent loss of various IPMCs made of Nafion$^{TM}$117(183$\mu$m thickness) has been experimentally investigated to find out the best combination of cation and solvent for minimal solvent loss in IPMCs and higher actuation force. For this purpose. experiments for the internal solvent loss measurement of IMPCs have been conducted for various combinations of cation and solvent. From the experiments, it was found that heavy water showed improvement in the operating time up to more than two minutes. in the tip force measurement of IPMCs, it was found that smaller and thicker IPMCs produced larger tip forces. However, the shorter IPMCs generated reduced actuation displacements and created flapping motion with decreased natural frequency. For the design of flapping device actuated by 5mm wide, 10mm long, 0.2mm thick IPMCs were used in the stacked form. Since the actuation force is a few gram-force, we stacked five IPMCs to improve actuation force. To amply the actuation force, rack-and-pin ion type hinge was used for the flapping device and insect (Cicadidae) wing was attached to the stacked IPMC actuator. In the flapping test, the device could generate flapping angle of 15$^{\circ}$ at 6Hz excitation by 2.5 voltage square wave input.