Reduction Techniques of the Pipe Line net Using According to DVGW
DVGW이론에 따른 상수관망의 부식방지를 위한 정수처리방안
- Choo Tai-Ho (Miryang National Univ.) ;
- Kim Ha-Il (Busan Water Authority)
- Published : 2005.11.01
Abstract
Leakage of waterworks pipe line net cause loss of water resources, additional foundation of pressurization facilities from pressure loss and soil weakening near leaked pipe line, etc. This is difficult to maintain and manage waterworks pipe line net and to cause serious economic loss. Rate of accounted water is better by monitoring always water pressure and flux, etc. from isolated region, positively dealing with leakage accident and preventing leakage from occurring. Actually after isolating region, average rate of accounted water in this region is 88.94% by continuously monitering control of water pressure and inflow rate. It is about 9.44% more than that of Busan metropolitan city in 2003, 79.5%.
상수도관망에서 발생하는 누수현상은 수자원의 손실뿐만 아니라 압력손실로 인한 추가적 가압 설비의 필요성 및 누수되는 관로 주변의 토질의 약화 등을 초래하여 관망의 유지관리를 어렵게 하고, 심각한 경제적 손실을 야기하고 있다. 이에 구역고립으로 인한 수압과 유량 등을 상시 모니터링하여 누수사고의 적극적인 대처와 누수발생을 미연에 방지함으로써 유수율을 향상 시킬 수 있다 .실제 구역고립 후 계속되는 수압 조절 및 유입유량의 모니터링으로 인하여 구역내 유수율 산정결과 평균 유수율은 88.94%로서 부산광역시 2003년도의 유수율 79.5%보다 9.44% 높게 조사되었다.