한국신재생에너지학회:학술대회논문집
- 한국신재생에너지학회 2005년도 제17회 워크샵 및 추계학술대회
- /
- Pages.579-582
- /
- 2005
IEC 규격에 따른 풍력 터빈 소음의 현장 실증
Field Test and Evaluation of Wind Turbine Noise according to IEC Standards
- 정철웅 (한국표준과학연구원 음향진동실) ;
- 정성수 (한국표준과학연구원 음향진동실) ;
- 정완섭 (한국표준과학연구원 음향진동실) ;
- 신수현 (한국표준과학연구원 음향진동실) ;
- 전세종 (한국표준과학연구원 유체유동실) ;
- 이생희 (한국표준과학연구원 유체유동실)
- Cheong, Cheol-Ung ;
- Jung, Sung-Su ;
- Cheung, Wan-Sup ;
- Shin, Soo-Hyun ;
- Chun, Se-Jong ;
- Lee, Sang-Hee
- 발행 : 2005.11.11
초록
The sound measurement techniques in IEC 61400-11 are applied to field test and evaluation of noise emission from 1.5 MW wind turbine generator (WTG) at Yongdang-Lee and 650 kW WTG at Hangwon-Lee in Jeju Island. Apparent sound power level, wind speed dependence and third-octave band levels are evaluated for both of WTGs. 1.5 MW WTG at Yongdang is found to emit lower sound power than 660 kW one at Hangwon, which seems to be due to lower rotating speed of the rotor of WTG at Yongdang. Equivalent continuous sound pressure level s (ECSPL) of 650 kW WTG at Hangwon vary more widely with speed than those of 1.5 MW WTG at Yongdang. The reason for this is believed to be the fixed blade-rotating speed of WTG at Yongdang. One-third octave band analysis of the measured data show that the band components around 400-500 Hz are dominant for 1.5 MW WTG at Yongdang and those around 1K Hz are dominant for 660 kW WTG at Hangwon.
키워드