Proceedings of the Korea Concrete Institute Conference (한국콘크리트학회:학술대회논문집)
- 2005.11a
- /
- Pages.749-752
- /
- 2005
Fire Resistance Performance of High Strength-Light Weight Concrete
고강도를 적용한 1종 경량골재 콘크리트의 내화특성
- Published : 2005.11.01
Abstract
Normally, the degradation of concrete member exposed to fire is largely dependent on the fire scale and fire condition. With all ensuring the fire resistance structure as a method of setting the required cover thickness to fire, the RC is significantly affected from the standpoint of its structural stability that the compressive strength and elastic modulus is reduced by fire. Thus, this study is concerned with experimentally investigating fire resistance of high strength-light weight concrete. From the test result, high strength-light weight concrete is happened explosive spalling. The decrease of cross section caused by explosive spalling made sharp increasing gradient of inner temperature.
Keywords