Proceedings of the KIEE Conference (대한전기학회:학술대회논문집)
- 2005.07c
- /
- Pages.2126-2128
- /
- 2005
Considerations on the TF Map using Partial Discharge Pulse Characteristics
부분방전 펄스특성을 이용한 TF Map에 대한 고찰
- Kim, Jeong-Tae (Daejin University) ;
- Kim, Nam-Joon (Daejin University) ;
- Chang, Yong-Moo (Hanyang University) ;
- Kim, Ji-Hong (Hanyang University) ;
- Koo, Ja-Yoon (Hanyang University)
- 김정태 (대진대학교 전기정보시스템공학과) ;
- 김남준 (대진대학교 전기정보시스템공학과) ;
- 장용무 (한양대학교 전자컴퓨터공학부) ;
- 김지홍 (한양대학교 전자컴퓨터공학부) ;
- 구자윤 (한양대학교 전자컴퓨터공학부)
- Published : 2005.07.18
Abstract
In this paper, it was investigated the applicability of TF analysis for the discrimination of air corona in on-site PD measurement. For the purpose, single and multiple discharges combined with oil discharges and air corona were generated and measured by use of artificial models and HFPD pulse detector. Through the TF analysis, data clusters could be classified each other in the TF Map, even in the case of multiple discharges. Therefore, it is known that TF analysis could be applied for the improvement of on-site PD measurement.
Keywords