Effects of AC Electric Field on the Stability of Laminar Lifted Flame in Coflow Jet

동축류 버너에서 층류 부상화염 안정화의 교류 전기장 효과에 관한 실험적 연구

  • Published : 2004.11.26

Abstract

The effect of electric fields on the stability of non-premixed laminar lifted flame in coflow jets has been investigated by applying high voltage alternative current (AC) to the nozzle of propane fuel. The stable lifted flame which exist in far field of jets, the liftoff height was not effected by applied voltage. This implies that the cold jet between the nozzle and flame base can be analyzed with the previous cold jet theory. Flame liftoff and reattachment velocities were also measured as function of applied voltage and frequency. The fuel jet velocity at flame liftoff and reattachment increased with increasing voltage, implying that the range of flame srability can be extended with the AC charging. However the liftoff velocity increased with frequency of AC charging on nozzle, whereas the reattachment velocity decreases with frequency. The liftoff and reattachment velocities were correlated linearly with voltage considering the effects of frequency.

Keywords