무전극등 안정기 시뮬레이션 연구

Modeling and Simulation of an Electrodeless lamp system

  • 발행 : 2004.05.07

초록

Characteristics of electrodelss lamp as a load of the ballast is different compared to normal fluorescent lamp because the lamp includes the magnetics for inductive discharging process. So somewhat different modeling is necessary to make a proper power match between the lamp and ballast. Modeling of an electrodeless lamps, Endura of Osram, is presented in this paper. Simulation with a result of experiment is given for a verification of proposed model.

키워드