Characteristic analysis of inductive contactless power transformer laid under the road/railway for performance improvement

도로/궤도 매립형 무접촉 집전장치의 전력전달 성능개선을 위한 특성해석

  • Published : 2004.10.01

Abstract

In this paper, the inductive power transformer using electromagnetic induction for the road/railway applied to contactless power transfer system is suggested and some ideas for power collector design to improve the power transfer performance are presented. The proposed the inductive power transformer is used for the light railway/road transportation system. which has a large air-gap and demands a large electrical power capability. But. low output power is generated due to a loosely coupled characteristic of the large air-gap. Therefore, double layer construction of secondary winding, which was divided in half to increase both output current and output voltage was suggested. In addition, the performance of inductive power transformer to alignment condition between the primary power line and the inductive power transformer was verified by computer simulation of 2kW model.

Keywords