Numerical simulation is conducted to clarify the heat transfer and fluid flow characteristics of HVAC(Heating, Ventilating and Air-Conditioning) for double' deck train. The HVAC system is installed under the roof of carbody. In the lay-out of HVAC system, air duct must be installed to supply air to 1st and 2nd floor respectively. The standard k-$\epsilon$ and LES models for turbulence and SIMPLE algorithm for pressure equation hased on finite volume method are used to solve the physic a] HVAC model. To assure convergence, QUICK scheme for momentum equation and the 2nd order upwind scheme for turbulent equations arc used. From the results of simulation, the temperature and velocity magnitude are also distributed uniformly in the interior of double-deck passenger car.