유체기계공업학회:학술대회논문집
- 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
- /
- Pages.70-77
- /
- 2004
토출구의 형상에 따른 원심 송풍기의 성능특성
Characteristics of Performance for Centrifugal Blower with Different Outlet Geometries
- 발행 : 2004.12.01
초록
Comprehensive investigation on the outlet's geometric shapes of a centrifugal blower with higher inlet resistance than an atmospheric pressure is carried out for improvements of its performance. Most unwanted behaviors of such blower are pulsating flows because of unbalance between inflows and outflows in a scroll casing. In order to reduce this undesirable phenomenon a triump is made for both the shape of outlet duct and an accessory structure inserted in the outlet port of the blower. The modification on the shape is concerned with the contraction of cross sectional area and the attached structure is for an intentional obstruction to cause a flow resistance. The details of the modification are examined for different cases and results. The methodologies for the work are performance evaluations including noise level and velocity measurements with PIV Consequently, the performance of improved system is close to that of the system operating with atmospheric pressure at the inlet.
키워드