수중에서의 이중 절연 방전관과 구형 유전체의 전계 분포 시뮬레이션

The Simulation of Electric Field Distribution of Dielectric Tube with Two Layers and Gloular Dielectric in Water

  • 이동훈 (경남대학교 전기공학과 대학원) ;
  • 박재윤 (경남대학교 전기전자공학부) ;
  • 박홍재 (경남대학교 전기공학과 대학원) ;
  • 고희석 (경남대학교 전기전자공학부)
  • 발행 : 2003.07.10

초록

This paper was simulated the electric field distribution in dielectric tube with two layers and spherical dielectric in water. The reactor was made up of the spherical dielectric that is diameter : 2.5[mm], ${\epsilon}_r$ : 5, 25, 100, 1000, 5000 respectively and two glass plate being 2[mm] thickness, ${\epsilon}_r$ : 5 as electrode. The discharge gap was 9[mm]. As a result of the simulation, in case of being about the same value between the dielectric constant of spherical dielectric and water, when the reactor was applied to high voltage, dielectric polarization characteristic was trending toward disappearance. To get more strong electric field, the dielectric constant should be higher comparatively, Increasing the spherical dielectric constant, the location of equippotential line was shifting from the interior to the exterior.

키워드