저 염소 TiN필름 제조를 위한 CVD 반응기 내의 유동해석

  • Published : 2003.12.01

Abstract

Flow modulation chemical vapor deposition process has been reported as an alternative way to obtain low resistivity, low residual chlorine content and good step-coverage titanium nitride film. Flow and concentration characteristics in a vertical FMCVD reactor are analyzed by using computational fluid dynamics method. The results show that 1.0 second as Cl reduction period is too short and there is still $TiCl_4$ gas above the holder at the end of the period. Time variation of $TiCl_4$ gas concentration on the holder shows that at least 3.0 second is necessary as Cl reduction time for the sake of film characteristics.

Keywords