A Study on the Cold Weather Concrete using High Early Strength Concrete

조강시멘트를 이용한 한중콘크리트의 특성평가 연구

  • 임채용 (쌍용양회공업㈜ 기술연구소 콘크리트연구실) ;
  • 엄태선 (쌍용양회공업㈜ 기술연구소 콘크리트연구실) ;
  • 유재상 (쌍용양회공업㈜ 기술연구소 콘크리트연구실) ;
  • 이종열 (쌍용양회공업㈜ 기술연구소) ;
  • 이순기 (쌍용양회공업㈜) ;
  • 이동호 (쌍용양회공업㈜)
  • Published : 2003.11.01

Abstract

Cold weather can lead to many problems in mixing, placing, setting time, and curing of concrete that can have harmful effects on its properties and service life. Korean Concrete Institute (KCI) defines cold weather as a period when the average daily air temperature is less $4^{\circ}C$ and recommends to cast concrete with special care such as shielding, heating and so on. The use of high early strength cements may improve the rate of hardening characteristics of concrete in cold weather by making it possible to achieve faster setting time and evolving more hydration heat than ordinary Portland cement. Higher early strength can be achieved using Type III cement especially during the first 7 days. The strength increase property of Type III cement at low temperature was studied. As a conclusion the heat or heat insulation curing period can be reduced to 50~75%. So, it can be used for cold weather concreting to reduce construction cost and extend the construction season.

Keywords