Fundamental Experiment of Dynamic Response for LNG Pilot Tank

LNG Pilot 탱크의 동특성 실험

  • 임윤묵 (연세대학교 사회환경시스템공학부) ;
  • 김문겸 (연세대학교 사회환경시스템공학부) ;
  • 조경환 (연세대학교 사회환경시스템공학부) ;
  • 박수용 (영산대학교 건축학부)
  • Published : 2003.09.01

Abstract

Korea Gas Corporation has recently constructed a LNG pilot tank with 1, 000㎥ capacity in Incheon, Korea. The main objective of this pilot tank construction is to accumulate field data under different operating conditions for the future use in design procedure, construction, and maintenance. As the part of the project, a field dynamic test, so-called modal test, is performed to obtain the dynamic characteristics of the pilot tank. This paper describes the instrumentation and measurement Process used in the testing. From the measured Frequency Response Functions (FRFs), resonant frequencies and corresponding mode shapes of the tank are extracted and provided. Also, these results are compared to those calculated from a finite element model. The change of dynamic characteristics of the pilot tank due to the effect of internal fluid and the possible structural deterioration will be investigated in near future.

Keywords