20층 비선형 벤치마크 빌딩에 대한 자기유변유체 감쇠기의 최적위치 결정

Optimal placement of MR dampers for 20-story nonlinear benchmark building

  • 장종우 (한국과학기술원 건설및환경공학과) ;
  • 조상원 (한국과학기술원 건설및환경공학과) ;
  • 이인원 (한국과학기술원 건설및환경공학과) ;
  • 윤우현 (경원대학교 산업환경대학원)
  • 발행 : 2003.09.01

초록

The objective of optimal placement of dampers for a structure is to maximize the effectiveness of the vibration control with the same number of dampers. While many optimal placement methods of linear viscous dampers have been proposed and used, there are only a few methods for MR dampers. Here some optimal location indices for MR dampers are proposed, which are similar to those for linear viscous dampers and show how large the structural responses on each floor we. Every time an additional MR damper is implemented, the optimal location index on each floor is measured, and then the next damper is installed on the floor with the maximum location index. In these sequential procedures, the peak interstory drift, the peak interstory velocity and the absolute acceleration of each floor are selected as the optimal location indeices. Four different earthquakes with various scales are loaded to the 20-story nonlinear benchmark building model (Otori et at. 2000, 2002). Passive On/Off algorithms are used in order to represent the control algorithm of MR dampers.