Evaluation of Time Dependent Tritium Concentration for Safety Analysis in Wolsong Tritium Removal Facility

월성 삼중수소 저장 시설 안전성 평가를 위한 시간에 따른 삼중수소 농도 평가

  • Published : 2003.11.01

Abstract

The objective of this to improve the reliability of the safety evaluation code for Wolsong Tritium Removal Facility(WTRF) which is on the development for environmental assessment. To achieve this, tritium concentrations calculated in the Wolsong Units of this study are compared with that of the existing reference. As the result, the tritium concentration in each Wolsong nuclear power plant unit just before operating WTRF is 60.9Ci/kg, 36.3Ci/kg, 30.0Ci/kg, 26.5Ci/kg under the assumption that the WTRF begins operation in 2005, respectively. This result is almost same with that of the existing reference. But the reducing rate of tritium concentration in the moderator is faster than that of the reference result Finally it is expected to drop below 10Ci/kg after WTRF operation. And this result is also similar with that of the existing reference.

본 연구의 목적은 월성의 삼중수소 저장 시설의 안전성 평가를 위해 개발 중인 환경영향 평가 코드의 시간에 따른 삼중수소 농도를 기존의 연구 결과와 비교하여 신뢰성을 높이기 위해 수행되어졌다. 그 결과 삼중수소 저장시설이 2005년에 가동된다고 가정하였을 때 가동시점에서의 월성 발전소 내의 삼중수소의 농도는 각 호기별로 60.9Ci/kg, 36.3Ci/kg, 30.0Ci/kg, 26.5Ci/kg로 기존의 문헌 결과 값과 거의 일치하는 결과를 얻었다. 그러나 TRF 시설의 가동에 따른 발전소별 농도 감소 속도는 기존 문헌 보다 더 빨리 감소하는 결과를 얻었으며 최종적으로는 각 발전소별 감속재 내의 삼중수소의 농도가 10Ci/kg 이하로 떨어지는 것은 같음을 확인 할 수 있었다.

Keywords