Study on the Separation of $^{55}Fe$, $^{90}FSr$$^{94}Nb$ in Radioactive Wastes

방사성 폐기물 내 $^{55}Fe$, $^{90}FSr$$^{94}Nb$의 분리 연구

  • Published : 2003.11.01

Abstract

Several radionuclides are considered as an object of the assesment to develop a scaling factor and a periodical verification method which are needed for the evaluation of radionuclide inventory of various radioactive wastes from nuclear power plants in Korea. A selective separation of $^{55}Fe$, $^{90}FSr$$^{94}Nb$ which should be recovered individually for the radiochemical analysis was described in detail. Sorption and desorption behaviours of ion exchange and extraction chromatographic resins for Fe, Sr, Nb and co-existing metal ions were Investigated using an artificial waste solution simulated of chemical composition of real radioactive wastes. Separation conditions available for the sequential recovery of these metal ions from a single sample were optimized to minimize a discharge of radioactive wastes produced through the analytical process and a radiation exposure to analysts. Their recovery yields were measured with reliability.

원자력발전소의 특성에 따라 서로 다른 방사성 폐기물의 핵종 재고량 평가에 필요한 척도인자와 주기적 검증방법을 개발하기 위하여 규제 대상의 핵종으로 검토되고 있는 다수의 핵종 중에서 개별분리가 요구되는 $^{55}Fe$, $^{90}FSr$$^{94}Nb$을 공존 핵종들로부터 선택적으로 분리, 회수할 수 있는 방법에 관하여 기술하였다. 고ㆍ액체 방사성 폐기물과 유사한 화학조성의 모의 방사성 폐기물 용해용액을 사용하여 이온교환수지법과 추출 크로마토그래피로 Fe, Sr, Nb 및 공존원소들의 흡ㆍ탈착거동을 조사하였다. 방사성 폐액의 발생과 분석자의 방사선 피폭을 최소화하기 위하여 한 개의 시료로부터 각 핵종을 순차적으로 회수하도록 분리조건을 최적화하였으며 확립된 분리조건에서 회수율을 측정하고 신뢰도를 평가했다.