Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference (한국윤활학회:학술대회논문집)
- 2002.05a
- /
- Pages.304-309
- /
- 2002
Experimental studies on the fretting wear of domestic steam generator tubes
국내 증기발생기 전열관 마열에 대한 실험적 연구
- Published : 2002.05.16
Abstract
Fretting wear test in room temperature water was performed to evaluate the wear coefficient of Inconel 600,690 (Pressurized Water Reactor, PWR) and Alloy 800 (CANadian DeuteriumUranium, CANDU) steam generator (SG) tubes against ferritic and martensitic stainless steels. The main focus is to compare the wear behaviors between Alloy 800 and Inconel alloys. Test conditions are