유전자 재조합 형광 단백질 발현 동물세포의 고정화 및 바이오센서의 개발
- Published : 2002.04.12
Abstract
Mammalian cell based biosensor kits are expected to be in assessment of samples toxicity more sensitive and accurate. A recombinant fluorescent Chinese Hamster Ovary (CHO) cell line was known to be responsive to the various toxicants Specially. KFC- AlO cell line. which contain the c-fos SRE::GFP plasmid (pKFG). was found to be able to detect toxicants sensitively. A biosensor kit was developed by using an immobilized KFC-A10 cell line. Immobilized recombinant fluorescent cells within agarose, known as a representative hydrogel matrix, have been maintained in the matrix viably and have shown constant fluorescent levels for long time. Immobilized cells have shown the ability to detect the chemical toxicity in the keep of fluorescent level as the metabolism is inhibited under toxic conditions.
Keywords