Experimental evaluation of sound Insulation performance of ceiling panels

천장재 차음성능의 실험 평가

  • 강현주 (한국기계연구원 음향연구그룹) ;
  • 김상렬 (한국기계연구원 음향연구그) ;
  • 김재승 (한국기계연구원 음향연구그) ;
  • 김현실 (한국기계연구원 음향연구그) ;
  • 김봉기 (한국기계연구원 음향연구그룹)
  • Published : 2002.05.01

Abstract

This paper deals with the factors affecting measurement of sound insulation performance of the ceiling panels. The factors to be experimently examined are as follows: sound diffuseness of the test room by investigating sound pressure distribution, Reverberation time, and influence of speaker location on measured results. Based on the investigation of sound pressure distribution over measuring points, it can draw a conclusion that rectangular shaped rooms as test rooms have a serious problem associated with the diffuse sound field.